APRIL AIR INSTALLATION

Minimal Installation
For Whole-Home Fresh Air

Aprilair installation
01

Only 1–2 Openings

No complex ductwork. The system can be installed through a wall or glass opening.

02

Flexible Placement

Suitable for outdoor, indoor, wall-mounted, ceiling-mounted or floor-standing installation.

03

Multi-Level Coverage

One Aprilair unit can support large open spaces and multi-level villa layouts.

04

Smart Control

Remote app control and indoor controller monitoring make daily operation easier.

INSTALLATION OPTIONS

Choose A Suitable Installation Method

Aprilair can be customized according to the actual house structure, wall position, equipment room, balcony, garden, terrace or indoor open space.

Outdoor

Exterior Wall Installation

The main unit is installed outside the building, while fresh air is delivered indoors through the outlet.

Indoor

Balcony / Utility Area

The unit can be installed in a closed balcony, equipment room or indoor utility area.

Wall Mounted

Compact Wall Placement

A neat solution for homes where wall space is available and maintenance access is required.

Floor Standing

With Optional Stand

For special spaces, the unit can be placed on the floor with a dedicated support stand.

INSTALLATION PROCESS

Six-Step Installation Tutorial

From drilling to final testing, the installation process is simple, structured and easy to maintain.

Drilling installation holes
STEP 01

Confirm Position And Drill Holes

Confirm the hole location and size before drilling. Drill the fixing holes for the fresh air unit and the opening for the indoor air outlet.

  • Confirm the exact installation position.
  • Drill the fixing holes for the main unit.
  • Drill the air outlet opening.
  • Reserve enough height for filter replacement.
  • Avoid load-bearing beams and unsafe wall areas.
Install fresh air unit
STEP 02

Install The Main Fresh Air Unit

Fix the Aprilair unit to the prepared location and reinforce it from all four corners. The unit should remain vertical, stable and easy to access.

  • Place the unit at the drilled position.
  • Secure the main body firmly.
  • Reinforce all four corners.
  • Check whether the unit is level and stable.
  • Make sure the front cover can be opened normally.
Install indoor air outlet
STEP 03

Install The Indoor Air Outlet

Install the indoor air outlet from inside the room and align it with the wall opening. The outlet should face an open area for better air distribution.

  • Install the outlet from the indoor side.
  • Align it with the wall or glass opening.
  • Keep the outlet surface neat and level.
  • Avoid blocking the outlet with furniture or curtains.
  • Confirm smooth airflow direction.
Installation dimension drawing
STEP 04

Check Dimensions And Cable Opening

Before final fixing, check the fresh air unit fixing holes, outlet opening, inlet position and power cable opening.

  • Check the main unit fixing hole position.
  • Check the outlet opening position.
  • Confirm the power cable opening.
  • Reserve enough maintenance space.
  • Keep the duct path clean and direct.
Connect duct from top
STEP 05

Connect And Secure The Duct

Connect the duct from the top of the fresh air unit, guide it through the wall or glass, and connect it with the indoor outlet.

  • Connect the duct to the top of the machine.
  • Guide the duct through the opening.
  • Connect the duct to the indoor outlet.
  • Fix the duct to prevent vibration.
  • Confirm that the duct is not bent or blocked.
Final installation testing
STEP 06

Connect Controller And Power On

Route the power cable indoors, fix it with a junction box, connect the controller and complete the final power-on test.

  • Route the power cable to the indoor side.
  • Confirm the socket position.
  • Fix the cable neatly with a junction box.
  • Connect and secure the controller.
  • Power on the system and test operation.
VILLA INSTALLATION PLAN

Typical Plan For Multi-Level Homes

For a 200–300 m² villa, one Aprilair unit can be placed outdoors, in an equipment room, garden area or terrace. The fresh air outlet is usually arranged in an open area such as the living room.

200–300 m²

Suitable reference range for many villa layouts.

One Unit

One unit can support multi-level fresh air delivery in open spaces.

Open Area Outlet

Living room or central open space is preferred for better air diffusion.

Garden / Outdoor Unit
Living Room Outlet
Controller
Upper Floor Airflow
INSTALLATION CASES

Outdoor And Indoor Installation References

Aprilair can adapt to different house types, including flat homes, duplex homes, three-floor villas, four-floor villas, classrooms and large open spaces.

OUTDOOR

Garden / Terrace / Exterior Wall

Recommended when outdoor wall space is available. It reduces indoor space occupation and keeps maintenance convenient.

INDOOR

Closed Balcony / Utility Room

Suitable for finished apartments or villas where the fresh air duct is introduced through a balcony wall opening.

MULTI-LEVEL

200–600 m² Villa Projects

Large airflow and high static pressure help support multi-level air renewal and balanced indoor air quality.

FINAL CHECK

Ready For Clean Fresh Air

After installation, check the unit fixing points, duct connection, indoor outlet, controller response, power connection, airflow direction and operation sound.

Request Installation Support